云平臺
企業簡介
發展歷程
企業資質
企業產品簡介
三、解決方案
??隨著物(wu)聯網技術的發展(zhan),商(shang)鋪物(wu)業預(yu)付(fu)(fu)費管(guan)理(li)(li)系統開始(shi)流行(xing),預(yu)付(fu)(fu)費管(guan)理(li)(li)系統采(cai)用(yong)(yong)了電(dian)(dian)(dian)(dian)能表作為計(ji)量(liang)裝置(zhi)。用(yong)(yong)戶(hu)先(xian)購(gou)電(dian)(dian)(dian)(dian)然后(hou)(hou)才能用(yong)(yong)電(dian)(dian)(dian)(dian),物(wu)業管(guan)理(li)(li)部門收取電(dian)(dian)(dian)(dian)費的預(yu)付(fu)(fu)款,等于電(dian)(dian)(dian)(dian)費提前回(hui)收了一(yi)個(ge)月,再根據用(yong)(yong)電(dian)(dian)(dian)(dian)量(liang)的多少進行(xing)多退少補。整個(ge)用(yong)(yong)電(dian)(dian)(dian)(dian)過程權(quan)責分明用(yong)(yong),電(dian)(dian)(dian)(dian)力供用(yong)(yong)雙(shuang)方自愿約定,用(yong)(yong)戶(hu)的購(gou)電(dian)(dian)(dian)(dian)量(liang)用(yong)(yong)完后(hou)(hou)即跳閘停電(dian)(dian)(dian)(dian),充值(zhi)后(hou)(hou)自動送電(dian)(dian)(dian)(dian),恢復用(yong)(yong)電(dian)(dian)(dian)(dian)。
預(yu)付費(fei)管(guan)理(li)系統為單個商鋪物(wu)業解決了(le)收費(fei)難的(de)問題,但是對于大型連鎖超市收費(fei),僅僅依靠預(yu)付費(fei)管(guan)理(li)系統還不足(zu)以解決問題,因此水電預(yu)付費(fei)云平臺在(zai)大型連鎖超市的(de)水費(fei)電費(fei)管(guan)理(li)中將會起到*關重要(yao)的(de)作用(yong)。
預付費云管理平臺(tai)采用分層分布式結(jie)構(gou)進行設計,主(zhu)要包括數據采集(ji)層、網絡(luo)傳輸層、數據中(zhong)心(xin)層以及客戶端層,具體網絡(luo)結(jie)構(gou)如(ru)下圖(tu)所示:
??各(ge)(ge)(ge)門(men)(men)店(dian)通(tong)(tong)過安裝預(yu)(yu)(yu)付(fu)(fu)費(fei)(fei)(fei)(fei)電表(biao),實(shi)現基(ji)礎(chu)數(shu)據的采(cai)集(ji)(ji)與計(ji)費(fei)(fei)(fei)(fei)控制;各(ge)(ge)(ge)預(yu)(yu)(yu)付(fu)(fu)費(fei)(fei)(fei)(fei)電表(biao)通(tong)(tong)過其(qi)自帶(dai)的通(tong)(tong)訊(xun)功能經(jing)過本地通(tong)(tong)訊(xun)網絡連接*通(tong)(tong)訊(xun)管(guan)理(li)(li)機,由通(tong)(tong)訊(xun)管(guan)理(li)(li)機經(jing)過4G路由器直接將預(yu)(yu)(yu)付(fu)(fu)費(fei)(fei)(fei)(fei)電表(biao)計(ji)費(fei)(fei)(fei)(fei)信息(xi)(xi)、充(chong)值信息(xi)(xi)等統一(yi)上傳*集(ji)(ji)團(tuan)總部服務器,實(shi)現各(ge)(ge)(ge)門(men)(men)店(dian)預(yu)(yu)(yu)付(fu)(fu)費(fei)(fei)(fei)(fei)用(yong)電的統一(yi)管(guan)理(li)(li);各(ge)(ge)(ge)門(men)(men)店(dian)物業(ye)管(guan)理(li)(li)人員(yuan)(yuan)(yuan)、財務管(guan)理(li)(li)人員(yuan)(yuan)(yuan)、業(ye)主、集(ji)(ji)團(tuan)工程管(guan)理(li)(li)人員(yuan)(yuan)(yuan)等,均可過PC、PAD、智能手機等終(zhong)端設(she)備通(tong)(tong)過B/S客戶端的方(fang)式登陸預(yu)(yu)(yu)付(fu)(fu)費(fei)(fei)(fei)(fei)管(guan)理(li)(li)平臺,*終(zhong)實(shi)現繳費(fei)(fei)(fei)(fei)充(chong)值、控制、查(cha)詢(xun)、票據打印等操(cao)作。
1、云平臺部署
各門(men)店現場(chang)可以省(sheng)去(qu)配(pei)置(zhi)預(yu)付費服務器、安(an)裝數據庫、短信(xin)貓等一系列工作(zuo),不但(dan)可以省(sheng)去(qu)很多硬件成本,還能大(da)大(da)減(jian)(jian)少調試和(he)維護(hu)成本;抄表信(xin)息通過網關(guan)實(shi)時上傳到云平臺,快速便捷,免去(qu)人工抄表,大(da)大(da)提高了人員辦公(gong)效率(lv),減(jian)(jian)少不必要的現場(chang)工作(zuo)人員。
2、系統規模
??接入表不(bu)受數量、地域限(xian)制,一個(ge)賬戶可以(yi)管理多個(ge)項目,系統(tong)設(she)計(ji)容量超過十萬個(ge)計(ji)量點,對于(yu)不(bu)進度(du)期(qi)不(bu)同(tong)規模的(de)商超門(men)店來說,可以(yi)隨時接入新(xin)的(de)計(ji)量點位
3、售電系統
??用(yong)戶(hu)通(tong)(tong)過瀏覽器即可(ke)進入預付費云(yun)系統,輸入相應用(yong)戶(hu)名及(ji)密(mi)碼,即可(ke)登陸(lu)系統界面進行操作。可(ke)以將用(yong)戶(hu)權限范(fan)圍內所有分布于**各(ge)個(ge)城市、各(ge)個(ge)區域(yu)商(shang)場(chang)門(men)店(dian)等通(tong)(tong)過地圖(tu)展示(shi),也可(ke)以通(tong)(tong)過地圖(tu)左(zuo)側列表(biao)展示(shi)出來,通(tong)(tong)過列表(biao)或(huo)者(zhe)地圖(tu)可(ke)以選擇索要進行操作的商(shang)場(chang)門(men)店(dian);財(cai)務集(ji)中管理,電量實時下發,并比對充值(zhi)次數防止作弊;支持(chi)一(yi)(yi)戶(hu)一(yi)(yi)電價,一(yi)(yi)戶(hu)一(yi)(yi)水價
4、用能分析數據公攤
??用(yong)戶和管理(li)員都可(ke)查詢預付費表(biao)(biao)或公共部位計(ji)量電表(biao)(biao)每天的(de)(de)用(yong)能(neng)狀況,可(ke)提供能(neng)耗(hao)分(fen)析(xi)+財(cai)務軌跡一(yi)(yi)體式(shi)綜合管理(li)報表(biao)(biao),包含用(yong)戶表(biao)(biao)的(de)(de)能(neng)耗(hao)、財(cai)務數(shu)(shu)據(ju)、能(neng)耗(hao)和財(cai)務的(de)(de)期(qi)初期(qi)末值等數(shu)(shu)據(ju)。方便總部對各(ge)門店用(yong)能(neng)數(shu)(shu)據(ju)進行(xing)統一(yi)(yi)分(fen)析(xi)。
四、結束語
??電(dian)力(li)是各個(ge)門店日常運營離不開(kai)的(de)(de)重(zhong)要能源,如(ru)何(he)合理(li)有效的(de)(de)利用(yong),如(ru)何(he)更加人性(xing)化(hua)的(de)(de)對(dui)各用(yong)戶(hu)的(de)(de)電(dian)費進(jin)行管理(li),實現(xian)企業(ye)管理(li)的(de)(de)進(jin)一步(bu)升*必(bi)將是今后(hou)一個(ge)長期的(de)(de)課題。現(xian)階(jie)段先消費、后(hou)用(yong)電(dian)已(yi)不能適應(ying)(ying)高科技(ji)、網絡化(hua)、快節奏的(de)(de)生活。而預(yu)付費管理(li)云平臺的(de)(de)推(tui)出和應(ying)(ying)用(yong),通(tong)過(guo)網路的(de)(de)傳(chuan)輸途徑(jing)從根本上解決了(le)(le)收(shou)費難、催(cui)費難的(de)(de)問題,并且(qie)將收(shou)費模式轉換到“先繳費,后(hou)用(yong)電(dian)”上來,大大降(jiang)低了(le)(le)集團企業(ye)電(dian)費墊資、欠費等(deng)壓力(li),使得大型連(lian)鎖超市在更加激烈的(de)(de)市場競爭中(zhong)贏得立足之地(di)。
圖(tu)(tu)1 供配(pei)電系統架構圖(tu)(tu)
監控系統結構
電(dian)(dian)力監控系統是指(zhi):通(tong)過執行(xing)(xing)規定(ding)功能來實現(xian)某一(yi)給(gei)定(ding)目標的(de)一(yi)些相互關聯(lian)單元的(de)組(zu)合(he),電(dian)(dian)力監控系統是利用先進的(de)計算機技(ji)(ji)術(shu)、現(xian)代電(dian)(dian)子(zi)技(ji)(ji)術(shu)、通(tong)信(xin)技(ji)(ji)術(shu)和信(xin)息處(chu)理(li)技(ji)(ji)術(shu)等實現(xian)對變(bian)電(dian)(dian)站二次設(she)備的(de)功能進行(xing)(xing)重新(xin)組(zu)合(he)、*化設(she)計,對變(bian)電(dian)(dian)站全(quan)部設(she)備的(de)運行(xing)(xing)情況執行(xing)(xing)監視(shi)、測量(liang)。
系統可分為三層結構:即現場設備層、網絡通訊層和平臺管理層。
現場設備層:包(bao)含(han)微(wei)機保(bao)護、智能操控、多功能儀表、計(ji)量表等設備(bei),用于采(cai)集站(zhan)內配電(dian)(dian)柜內電(dian)(dian)氣運行(xing)參數、開關狀態(tai)、電(dian)(dian)氣接(jie)點(dian)溫(wen)度(du)等數據(ju),同時分別在每處10kV變配電(dian)(dian)所配置1套直流電(dian)(dian)源,保(bao)障現場設備(bei)良好的運行(xing)環境(jing)。
網絡通訊層:包含ANet-2E8S智能(neng)網(wang)(wang)關(guan)。網(wang)(wang)關(guan)主動采集(ji)現場設備(bei)層設備(bei)的數據,并(bing)可(ke)進行(xing)規(gui)約轉換,數據存儲,分(fen)散(san)變(bian)電所通(tong)過數據采集(ji)箱(內置智能(neng)網(wang)(wang)關(guan))采集(ji)數據通(tong)過光(guang)纖上傳(chuan)*消(xiao)控室電力監控系統平臺。
平臺管理層:電(dian)力監控系(xi)統(tong)(tong)平臺、數據基礎設施管理系(xi)統(tong)(tong)DCIM。
圖2 監(jian)控系統網絡結(jie)構圖
解決方案
方案綜述
本項目(mu)10kV開(kai)閉(bi)所1座,區域變電(dian)所4座,此項目(mu)變、配電(dian)所布置(zhi)深(shen)入負(fu)荷(he),采(cai)取高低壓(ya)配電(dian)室(shi)(shi)(shi)、變壓(ya)器室(shi)(shi)(shi)及電(dian)力電(dian)池室(shi)(shi)(shi)貼近負(fu)荷(he)的布局(ju)在(zai)各層設置(zhi)變壓(ya)器和(he)低壓(ya)配電(dian)室(shi)(shi)(shi)、電(dian)力電(dian)池室(shi)(shi)(shi),向數據機(ji)房(fang)設備供電(dian)。
其中一(yi)層(ceng)為10kV開(kai)閉(bi)(bi)所(suo)、二層(ceng)、三層(ceng)、四層(ceng)以及地下一(yi)層(ceng)為10kV變壓(ya)器及0.4kV開(kai)關(guan)室。消控室位于一(yi)層(ceng)10kV開(kai)閉(bi)(bi)所(suo)內。
10kV開(kai)閉所一次系統圖(tu)如圖(tu)1所示,共有(you)48面(mian)開(kai)關(guan)柜(ju),分別為:4面(mian)進線(xian)隔離(li)柜(ju)、4面(mian)進線(xian)柜(ju)、24面(mian)出線(xian)柜(ju)、4面(mian)計量柜(ju)、4面(mian)PT柜(ju)、4面(mian)母(mu)聯(lian)柜(ju)、4面(mian)油機進線(xian)柜(ju)。
圖3 10kV供(gong)配電一(yi)次系統圖
區域變(bian)電(dian)(dian)(dian)所(suo)10kV采(cai)用(yong)多回路電(dian)(dian)(dian)源(yuan)供(gong)電(dian)(dian)(dian),采(cai)用(yong)10kV變(bian)電(dian)(dian)(dian)所(suo)內高(gao)壓(ya)(ya)(ya)(ya)計量。變(bian)壓(ya)(ya)(ya)(ya)器(qi)出線柜裝設定時(shi)(shi)限過流、速斷、零(ling)序、失壓(ya)(ya)(ya)(ya)報(bao)警,干(gan)式變(bian)壓(ya)(ya)(ya)(ya)器(qi)超溫(wen)跳閘保護,高(gao)溫(wen)報(bao)警。低壓(ya)(ya)(ya)(ya)配電(dian)(dian)(dian)柜采(cai)用(yong)固(gu)定分隔柜,配電(dian)(dian)(dian)柜進出線電(dian)(dian)(dian)纜(lan)、插接母(mu)線采(cai)用(yong)上進上出方式,變(bian)壓(ya)(ya)(ya)(ya)器(qi)不允許并列運(yun)行(xing),同(tong)一套低壓(ya)(ya)(ya)(ya)系(xi)統市電(dian)(dian)(dian)進線、聯(lian)絡(luo)采(cai)用(yong)自動電(dian)(dian)(dian)源(yuan)轉(zhuan)換系(xi)統,三者(zhe)只(zhi)能任合其中二個,保證兩路電(dian)(dian)(dian)源(yuan)進線開關和聯(lian)絡(luo)開關不能同(tong)時(shi)(shi)投入。變(bian)壓(ya)(ya)(ya)(ya)器(qi)供(gong)電(dian)(dian)(dian)采(cai)用(yong)M(1+1)配置,平時(shi)(shi)運(yun)行(xing)時(shi)(shi)每(mei)臺變(bian)壓(ya)(ya)(ya)(ya)器(qi)的(de)負荷(he)率不大于50;當一臺變(bian)壓(ya)(ya)(ya)(ya)器(qi)故(gu)(gu)障(zhang)時(shi)(shi),另一臺變(bian)壓(ya)(ya)(ya)(ya)器(qi)可帶(dai)起全部負荷(he)。(注:負荷(he)計算時(shi)(shi)按"當一臺變(bian)壓(ya)(ya)(ya)(ya)器(qi)故(gu)(gu)障(zhang)時(shi)(shi),另一臺變(bian)壓(ya)(ya)(ya)(ya)器(qi)可帶(dai)起全部負荷(he)"計算)。
圖(tu)4 區(qu)域(yu)10kV變(bian)電所(suo)10kV進(jin)線(xian)部分(fen)一次系(xi)統(tong)圖(tu)
圖5 區域10kV變電(dian)所低壓配電(dian)部分一次系統圖
功能需求
①本地數據采集與轉發
電(dian)力監(jian)控系統需采(cai)集設備數(shu)量(liang)共計(ji)88臺,同時將采(cai)集的數(shu)據中(zhong)每個配電(dian)房計(ji)量(liang)柜的電(dian)量(liang)數(shu)據上傳*數(shu)據的DCIM平臺,根據轉發數(shu)據類型(xing)主要分為(wei)遙(yao)(yao)測、遙(yao)(yao)信(xin)、電(dian)能三(san)類數(shu)據,部分數(shu)據展示如下:
遙測量
遙信量
電
②二次防護需求
為了加(jia)強(qiang)(qiang)本工程供配(pei)電系統,對(dui)本項(xiang)目電氣(qi)二次部分(fen)(fen)加(jia)強(qiang)(qiang)防護(hu)(hu),10kV進線(xian)采(cai)用(yong)過(guo)(guo)流(liu)、速(su)斷(duan)、零(ling)序保(bao)護(hu)(hu);出線(xian)采(cai)用(yong)過(guo)(guo)流(liu)、速(su)斷(duan)、零(ling)序保(bao)護(hu)(hu);變壓(ya)(ya)器(qi)(qi)(qi)設(she)(she)置過(guo)(guo)流(liu)、速(su)斷(duan)、溫度保(bao)護(hu)(hu)。電能計量設(she)(she)計采(cai)用(yong)高壓(ya)(ya)集中計量,在每路(lu)10kV電源進線(xian)處設(she)(she)置專(zhuan)用(yong)計量裝(zhuang)(zhuang)置,并(bing)可根據要求(qiu)設(she)(she)置低壓(ya)(ya)電力分(fen)(fen)表。低壓(ya)(ya)保(bao)護(hu)(hu)裝(zhuang)(zhuang)置采(cai)用(yong)主進斷(duan)路(lu)器(qi)(qi)(qi)、聯絡斷(duan)路(lu)器(qi)(qi)(qi)設(she)(she)過(guo)(guo)載(zai)長延時(shi)、短路(lu)短延時(shi)和瞬(shun)時(shi)保(bao)護(hu)(hu)脫扣器(qi)(qi)(qi),其他(ta)低壓(ya)(ya)斷(duan)路(lu)器(qi)(qi)(qi)設(she)(she)過(guo)(guo)載(zai)長延時(shi)、瞬(shun)時(shi)脫扣器(qi)(qi)(qi),部分(fen)(fen)回(hui)路(lu)設(she)(she)(分(fen)(fen)勵(li))脫扣器(qi)(qi)(qi)。
③系統硬(ying)件配(pei)置需求(qiu)
系統功能
實時監測
Acrel-2000Z電(dian)(dian)(dian)力監(jian)控系(xi)統人機界(jie)面友好,能夠以配(pei)(pei)電(dian)(dian)(dian)一(yi)次圖的形式直(zhi)觀顯(xian)示配(pei)(pei)電(dian)(dian)(dian)線路(lu)(lu)的運行狀(zhuang)態(tai)(tai),實時(shi)監(jian)測各回路(lu)(lu)電(dian)(dian)(dian)壓、電(dian)(dian)(dian)流、功率、功率因數等(deng)電(dian)(dian)(dian)參數信(xin)(xin)息(xi),動態(tai)(tai)監(jian)視各配(pei)(pei)電(dian)(dian)(dian)回路(lu)(lu)斷路(lu)(lu)器(qi)、隔離開關(guan)、地刀等(deng)合(he)、分閘(zha)狀(zhuang)態(tai)(tai)及有關(guan)故(gu)障、告(gao)警等(deng)信(xin)(xin)號(hao)(hao)(hao)。其(qi)中,10kV配(pei)(pei)電(dian)(dian)(dian)系(xi)統中監(jian)測的開關(guan)量主要有:斷路(lu)(lu)器(qi)分、合(he)閘(zha)信(xin)(xin)號(hao)(hao)(hao),手車(che)工作、試驗(yan)位置(zhi)信(xin)(xin)號(hao)(hao)(hao),遠方/就(jiu)地切換位置(zhi)信(xin)(xin)號(hao)(hao)(hao)、彈(dan)簧儲能狀(zhuang)態(tai)(tai)信(xin)(xin)號(hao)(hao)(hao)、接地刀合(he)分信(xin)(xin)號(hao)(hao)(hao)、變壓器(qi)超溫跳閘(zha)信(xin)(xin)號(hao)(hao)(hao)、高溫報警信(xin)(xin)號(hao)(hao)(hao),保護(hu)跳閘(zha)信(xin)(xin)號(hao)(hao)(hao)和(he)事故(gu)預告(gao)信(xin)(xin)。
圖(tu)6 實時監測主界面圖(tu)
電參量查詢
在配電(dian)一(yi)次圖中,可(ke)以直接查看該回路(lu)詳細電(dian)參量,包括三(san)相(xiang)電(dian)流、三(san)相(xiang)電(dian)壓、三(san)相(xiang)總有功(gong)功(gong)率(lv)、總無功(gong)功(gong)率(lv)、總功(gong)率(lv)因(yin)數、正向有功(gong)電(dian)能等,并可(ke)以查看24小時相(xiang)電(dian)流趨勢曲線。
圖(tu)(tu)7 電參(can)量查(cha)詢界面圖(tu)(tu)
運行報表
能查詢各回(hui)路或設備(bei)指定時(shi)間的(de)運行參數(shu),報(bao)表中顯示電(dian)(dian)參量信息應包括:各相(xiang)(xiang)電(dian)(dian)流(liu)、三相(xiang)(xiang)電(dian)(dian)壓、總功(gong)率因數(shu)、總有(you)功(gong)功(gong)率、總無功(gong)功(gong)率、正向有(you)功(gong)電(dian)(dian)能等(deng)。
歷史事件查詢
能夠對遙信變位,保護動作、事(shi)(shi)故(gu)跳閘,以(yi)及電壓(ya)、電流、功(gong)率(lv)、功(gong)率(lv)因(yin)數(shu)越限等事(shi)(shi)件記錄進行存儲和管(guan)理,方便(bian)用戶對系統(tong)(tong)事(shi)(shi)件和報警進行歷史追溯,查詢統(tong)(tong)計(ji)、事(shi)(shi)故(gu)分析。
電能統計報表
具備定時抄表匯總統(tong)(tong)計(ji)功能(neng),用戶可以自(zi)由查(cha)詢自(zi)系統(tong)(tong)正(zheng)常(chang)運行以來(lai)任意時間(jian)段(duan)內各配電節點的用電情況(kuang),即該(gai)節點進線用電量(liang)與(yu)各分支回路消耗電量(liang)的統(tong)(tong)計(ji)分析(xi)報表。
圖8 電運行統計報表界(jie)面圖
網絡拓撲圖
系(xi)統(tong)支持實時(shi)監視(shi)接入系(xi)統(tong)的(de)(de)各設備(bei)(bei)的(de)(de)通信(xin)狀態,能夠完(wan)整(zheng)的(de)(de)顯(xian)示整(zheng)個系(xi)統(tong)網(wang)絡結構;可在(zai)線(xian)診斷設備(bei)(bei)通信(xin)狀態,發生(sheng)網(wang)絡異常時(shi)能自動在(zai)界面上顯(xian)示故(gu)障(zhang)設備(bei)(bei)或元件及(ji)其故(gu)障(zhang)部(bu)位。
圖(tu)9 站內設備系統網絡拓撲圖(tu)
圖 1 電氣火災發生的原因
04
電氣火災監控系統應用要求
電氣火災監控系統(tong)設計應用的(de)(de)技術(shu)(shu)要(yao)求結合(he)上述對醫院電氣火災的(de)(de)特點(dian)與(yu)原(yuan)因,在進行電氣火災監控系統(tong)設計和應用中,需要(yao)滿足以下基(ji)本功能與(yu)技術(shu)(shu)要(yao)求。
(1)能夠對電氣設備運行過程中的漏電電流值、配電箱中的溫度值進行實時監測。如(ru)超過(guo)設(she)定(ding)值及(ji)時報警提示,并可以對(dui)(dui)電氣設(she)備(bei)的運行及(ji)其線(xian)路(lu)連接進行控(kong)制,從而對(dui)(dui)電氣設(she)備(bei)與線(xian)路(lu)進行有效保護。
(2)具備相應的記憶、顯示以及打印等功能。電(dian)(dian)氣火災監(jian)(jian)控系(xi)統(tong)在運行中(zhong),能夠通過探測(ce)監(jian)(jian)控器對(dui)三(san)相(xiang)(xiang)電(dian)(dian)源以(yi)(yi)及每(mei)相(xiang)(xiang)電(dian)(dian)流(liu)值(zhi)(zhi)以(yi)(yi)及漏電(dian)(dian)電(dian)(dian)流(liu)值(zhi)(zhi)、配電(dian)(dian)箱中(zhong)的溫度值(zhi)(zhi)實時(shi)監(jian)(jian)控顯示,并(bing)且其(qi)系(xi)統(tong)能夠對(dui)供電(dian)(dian)系(xi)統(tong)各支路運行狀態,以(yi)(yi)及動態參數、操作內容進行保存,方便查詢打印,必要時(shi)通過網絡將(jiang)報警信息以(yi)(yi)及部位(wei)傳輸到指定(ding)的手機(ji)上。
(3)具有良好的可操作性。電(dian)氣火災(zai)監控(kong)(kong)系(xi)統中(zhong)的探(tan)測控(kong)(kong)制(zhi)器(qi)應(ying)(ying)具有易操(cao)作的特征,能(neng)夠(gou)(gou)使操(cao)作者方便(bian)(bian)對(dui)(dui)其(qi)控(kong)(kong)制(zhi)參數進(jin)(jin)行(xing)設(she)定,并(bing)通(tong)過(guo)(guo)控(kong)(kong)制(zhi)器(qi)的顯示屏方便(bian)(bian)對(dui)(dui)供(gong)電(dian)參數和(he)運(yun)行(xing)狀態進(jin)(jin)行(xing)了解。此(ci)外,其(qi)系(xi)統中(zhong)主控(kong)(kong)制(zhi)計算機的人機界面交互良(liang)好(hao),能(neng)夠(gou)(gou)為操(cao)作者進(jin)(jin)行(xing)供(gong)電(dian)系(xi)統運(yun)行(xing)觀察,并(bing)通(tong)過(guo)(guo)不同顏色(se)顯示對(dui)(dui)其(qi)工作狀態進(jin)(jin)行(xing)區別,便(bian)(bian)于掌(zhang)握和(he)操(cao)作應(ying)(ying)用。
(4)能夠進行整定值調整支持。電氣火災監控系(xi)統的設計(ji)和(he)應(ying)用中(zhong),由于其系(xi)統內部的探測控制(zhi)器(qi)是采(cai)用微處(chu)理器(qi)控制(zhi),不(bu)僅具有較好的靈活性、運算速度快、可調節(jie)的范圍(wei)較廣等特征*勢(shi),而(er)且能夠在(zai)較為廣泛(fan)的保護范圍(wei)內對整定值進(jin)行合理選擇(ze)與調整,以促(cu)進(jin)其工(gong)作在(zai)一個合理區域。
(5)具有電氣設備試驗、預警和斷電操作等功能。電氣(qi)火災監控系統(tong)在實際應(ying)用中,為保(bao)證系統(tong)正常運(yun)(yun)行,需(xu)要(yao)通(tong)過系統(tong)中的主(zhu)控制計(ji)算機定期進行試驗信號,對其是否存在故(gu)障進行判斷,一旦(dan)出現(xian)故(gu)障可(ke)報警提示同時(shi)可(ke)以切斷故(gu)障部位,避免對整個(ge)電氣(qi)防火監控系統(tong)的正常運(yun)(yun)行造成影響。
05
電氣火災監控系統在醫院的應用
剩余電流式電氣火災監控設備的有效應用
對(dui)于電(dian)(dian)氣(qi)(qi)火災監(jian)控系統中的(de)(de)(de)此類型監(jian)控設備而言,其主(zhu)要(yao)是通過(guo)監(jian)測相(xiang)關(guan)電(dian)(dian)線和電(dian)(dian)纜(lan)在(zai)泄漏時(shi)所發(fa)生(sheng)的(de)(de)(de)電(dian)(dian)流(liu)變化,實(shi)現對(dui)其*緣(yuan)狀態的(de)(de)(de)有(you)效檢測。在(zai)此情(qing)況下,若(ruo)是地跌中的(de)(de)(de)相(xiang)關(guan)電(dian)(dian)氣(qi)(qi)設備在(zai)實(shi)際(ji)運行時(shi)出現電(dian)(dian)氣(qi)(qi)故(gu)障(zhang),其發(fa)生(sheng)故(gu)障(zhang)的(de)(de)(de)位置就一定是電(dian)(dian)流(liu)在(zai)穿過(guo)電(dian)(dian)流(liu)互感器時(shi)進入大地的(de)(de)(de)實(shi)際(ji)位點(dian)。基于此,為了能夠更好將這一類監(jian)控探測器的(de)(de)(de)實(shi)質(zhi)性作(zuo)用(yong)充(chong)分(fen)的(de)(de)(de)發(fa)揮出來,相(xiang)關(guan)人員(yuan)應在(zai)合理選(xuan)擇安(an)裝(zhuang)(zhuang)位置的(de)(de)(de)同時(shi)對(dui)其進行有(you)效安(an)裝(zhuang)(zhuang)。
ARCM型剩余電流(liu)式(shi)電氣火災監控探(tan)測(ce)器,可對回路(lu)中的剩余電流(liu)互(hu)感器進行(xing)有(you)效(xiao)檢(jian)測(ce),探(tan)測(ce)器支持開口式(shi)和閉口式(shi)多(duo)種安裝方式(shi),可以有(you)效(xiao)解決(jue)現場互(hu)感器的安裝問題。
圖(tu)1 低壓配電室現場安裝(zhuang)
圖2 強電間現場安裝(zhuang)
測溫式電氣火災監控設備的有效應用
由(you)于(yu)電(dian)器(qi)負荷(he)的(de)(de)(de)過載,會導致(zhi)線纜的(de)(de)(de)電(dian)流過流,并蘇浙電(dian)流的(de)(de)(de)不斷(duan)(duan)提升(sheng),地(di)(di)鐵中(zhong)相關電(dian)氣設(she)備的(de)(de)(de)電(dian)阻數值正在(zai)持續(xu)上升(sheng),溫度升(sheng)高,而(er)測(ce)溫式(shi)監(jian)控(kong)探測(ce)器(qi)設(she)備的(de)(de)(de)有效(xiao)應(ying)用便是在(zai)此(ci)運(yun)行(xing)原理(li)的(de)(de)(de)基礎上開展相關工(gong)作的(de)(de)(de)。對于(yu)此(ci)類監(jian)控(kong)探測(ce)器(qi)設(she)備而(er)言,其(qi)主(zhu)要是以測(ce)溫傳感器(qi)為依靠(kao)進行(xing)實際工(gong)作,一般會在(zai)一些發(fa)熱現(xian)象比較明顯(xian)、發(fa)熱概率比較高的(de)(de)(de)位置進行(xing)實際安(an)裝。如(ru),電(dian)纜接(jie)(jie)頭(tou)和(he)開關觸點等(deng)。此(ci)外,地(di)(di)鐵的(de)(de)(de)相關部門也會將此(ci)類監(jian)控(kong)探測(ce)器(qi)設(she)備安(an)裝在(zai)開關和(he)底座的(de)(de)(de)接(jie)(jie)觸區(qu)域,以實現(xian)對低壓配電(dian)設(she)備使用狀(zhuang)態(tai)和(he)運(yun)行(xing)狀(zhuang)態(tai)的(de)(de)(de)有效(xiao)檢測(ce)。比如(ru)三(san)*負荷(he)的(de)(de)(de)總斷(duan)(duan)路器(qi)接(jie)(jie)口處等(deng)。只有這樣(yang),才能(neng)在(zai)實現(xian)有效(xiao)監(jian)測(ce)的(de)(de)(de)同時,避(bi)免(mian)出現(xian)電(dian)氣火災的(de)(de)(de)相關事故。
ARCM型測(ce)溫型電氣火(huo)災監控探測(ce)器主要配合ARCM-NTC型測(ce)溫傳感器,可以對線纜的溫度進行(xing)有效檢測(ce)。
圖(tu)3 ARCM-NTC
圖4 ARCM-NTC現場安(an)裝
限流式保護器的有效應用
隨著(zhu)社(she)會經濟的飛速發(fa)(fa)展(zhan),社(she)會電(dian)(dian)氣化程度(du)不斷提高,用(yong)電(dian)(dian)負荷過(guo)大(da)、線路(lu)(lu)短路(lu)(lu)等原因導致電(dian)(dian)氣火(huo)(huo)災(zai)發(fa)(fa)生越來越頻繁,使得火(huo)(huo)災(zai)數(shu)量呈上升趨勢,地鐵(tie)項目中的電(dian)(dian)氣火(huo)(huo)災(zai)也(ye)屢見(jian)不鮮。為了防(fang)止(zhi)電(dian)(dian)氣火(huo)(huo)災(zai)事故的發(fa)(fa)生,低壓配電(dian)(dian)系統(tong)已普遍采用(yong)了智能化的電(dian)(dian)子(zi)設備和(he)(he)系統(tong)對(dui)用(yong)戶現場(chang)的電(dian)(dian)氣線路(lu)(lu)進行監(jian)測、報(bao)警和(he)(he)控制。但(dan)是,對(dui)于造成(cheng)電(dian)(dian)氣火(huo)(huo)災(zai)危害嚴重、占(zhan)比大(da)的電(dian)(dian)路(lu)(lu)短路(lu)(lu)故障(zhang),始終缺乏有效的限流短路(lu)(lu)保(bao)護手段以預防(fang)和(he)(he)解(jie)除故障(zhang)。
安科瑞(rui)生產的ASCP型限流式保(bao)護器,可以對回路的短路進行有效保(bao)護。
圖5 ASCP限流(liu)式保護器現場安裝
06
結語
綜上所述(shu),對電氣火(huo)(huo)災監控(kong)(kong)系統(tong)(tong)在醫(yi)院(yuan)的應(ying)用(yong)進行(xing)(xing)研究(jiu),結(jie)合醫(yi)院(yuan)建筑電氣線路(lu)特點,采用(yong)電氣防火(huo)(huo)監控(kong)(kong)系統(tong)(tong),加強對醫(yi)院(yuan)電氣火(huo)(huo)災原因的監測分析,及時進行(xing)(xing)電氣火(huo)(huo)災隱患**,對確保醫(yi)院(yuan)建筑電氣的正常(chang)運行(xing)(xing),具(ju)有(you)十(shi)分積*的意義。
公司動態
行業動態